Data Logging:
- 8 analog channels --12 bit – 0 to 5V range, 0.025% resolution
- Corsa Data Logger provides regulated 5v power to sensors
- 2 speed channels – 16 bit – 1 RPM to 16 kHz
range
- Adaptive threshold on speed channels – 0.1v to 5v range.
Works with speed inputs as small as +0.200V or as large as +/-
120V
- All channels use same sampling rate. User-selectable 1 to 20
samples per second for Basic; 1-50 samples per second for Professional
- Input from optional lap beacon and “run/stop”
switch
- Internal real time clock for events
- AutoStart configurable to trigger on any level of any channel
- 2 alarm outputs – user configurable - trigger on any
level of any channels
- 20 or more additional channels via expansion bus
Recording time example: Corsa Data Logger standard systems provides
10 data channels; 8 analog and 2 speed. At 10 samples per second,
the system can record for over 26 minutes before filling memory.
After wireless download, the system is immediately ready to resume
recording if desired.
Communication:
- Small PC-mounted radio with USB interface
- 900mHz band, 32k bps (European specification radio available)
- 1000 foot typical range line of sight, 1/2 mile with Professional
- All Corsa Data Logger communications are password protected
Physical, Power, Environment Requirements:
- Small and light -- 4.5" x 3.4" x 1.3", 8.7 oz.
- Requires power from vehicle or other battery -- 11 to 18 volts
- Low current drain, 50mA typical
- All memory is retained when power goes off
- Water-resistant case and connectors
- Operating temperature 32 deg. F to 150 deg. F
Other features:
- 2 alarm outputs - Configurable for light or relay. 0.5A max
current
- Built-in LED’s visually indicate status – power,
run, error
- Built-in LED's for checking RPM / Speed hookup
- Input for optional run switch and output for run light
Accessories and Expansion Modules:
- Sensors - wide variety of ranges for speed, pressure, and position
- EZ-AC1, 2, or 3 - Adds 1, 2, or 3 axis accelerometer data ;
+/- 5g range
- EZ-TK8 - Adds eight K type thermocouple channels, plus 2 speed
channels
- EZ-EXP8 - Adds eight analog channels, plus 2 speed channels
- EZ-AFR - Adds 1 or 2 channels of wide-band air/fuel ratio data
- Lap timer with trackside beacon
- Manual “run/stop” switch
- EZ-J1939 adds 40+ channels of SAE J1939 CAN bus data
- EZ-POINTS - Adapter for points-type ignition systems
- Battery kit for vehicles without 12V power systems
EZ-TK Thermocouple Interface:
- Adds 10 channels (8 temp, 2 speed) to Data Logger capacity
- Measurement range 32 to 2000 deg. F (0 to 1090 deg. C )
- 12 bits (0.5 deg. F) resolution
- Dimensions - 6.3” x 2.4” x 1.3”. Weight 7.8
oz.
- Uses K type thermocouples with industry-standard mini 2-blade
connectors
- Built-in cold junction compensation, calibration, and linearization
- Open thermocouple detection – goes full minus
- Handles floating or grounded junction thermocouples
- Withstands at least +/- 12v applied to thermocouples
EZ-ACx Accelerometer Expansion Module:
- Adds 1, 2, or 3 channels of analog accelerometer data to Data Logger
system
- Range is plus/minus 5 g’s
- 12 bits (.0034 g’s ) resolution
- Dimensions 3.4" x 2.8" x 1.3", Weight 5.4 oz.
- Easily mounts to floor or other location on vehicle
- Adds 2 speed channels -32 bit -about 1 RPM to 16 kHz range
EZ-AFR Wideband Air / Fuel Ratio Module
- Range 8.5:1 to 20:1 on gasoline
- Works with all fuels (reduced life with leaded gas)
Corsa Data Logger with Compact Flash (EZ2-CF):
- Designed for easy automatic operation in endurance or field
test applications
- Add Compact Flash (CF) memory card socket and door
- Same case style as standard Corsa Data Logger. Dimensions are 4.4" x 4.3"
x 1.3".
- Water resistant door for CF card insertion / removal
- Configure EZ2-CF via radio or PC
- Up to 1 GB CF cards available
- Typical power consumption 300mA at 11 to 18 volts
- Included CF card reader/writer connects to your computer’s
USB port
Record Time Example: A Corsa system configured for vehicle field
testing includes an EZ2-CF with a 512Mb memory card and an EZ-TK8.
The system provides 20 channels of data; 16 analog, 8 of which are
temperatures, and 4 speed channels. Recording at 5 samples per second,
this system provides over 400 hours (18 days!) of data logging capacity.
Replacing the CF card in the system provides an additional 400+
hours of capacity each card. Data can be downloaded via CF card or EZ-Radio.
EZ-CAN Interface:
- Monitor up to 40 channels (CAN ID's) on the vehicle bus
- Configured through Data Logger systems (including EZ2-CF)
- Compatible with SAE J1939 (heavy truck standard)
- Data buffering and storage to match CAN data rate with sampling
rate
- Waterproof box and connectors
- Power the entire Corsa Data Logger system from the J1939 connector
- Custom software extensions available - please inquire
EZ-EXP8 Analog Expansion Module:
- Adds 8 analog channels --– 12 bit A/D – 0 to 5V range,
0.025% resolution
- Adds 2 speed channels – 16 bit – about 1 RPM to 16 kHz
range
- Provides regulated 5V power to sensors
- Use multiple expansion modules to add additional channels
|